HT-9601 / 4G smart mobile control switch

Equipment on site.
Control in your hand.

HT-9601 combines phone-based switching, an LCD and ambient temperature and humidity sensing for everyday control, schedules and shared access.

HT-9601
HT-9601 · LCD · External antenna
4G

Remote phone control

LCD

Status & ambient readings

AC 36–400V

Operating voltage

1 year

Included overseas data

01 / HT-9601

From a single switch to daily management.

Bring everyday controls, on-site information and operating schedules together.

Remote switching

Control across locations when the phone and device are connected, without the direct radio range limit of a handheld remote.

Manual control

SET, ON and OFF buttons keep basic operation accessible at the device.

Ambient sensing

Collect and display ambient temperature and humidity at the installation location.

Schedules & cycles

Set switching times and repeating tasks around your work.

Shared access

Share access using a device key to support team operation.

Power-loss SMS

Notify the main account of a power interruption to help identify supply issues.

02 / 4G

No on-site Wi-Fi required.
Connect over 4G.

The device uses a mobile network and is operated through a supported phone interface. Remote operation is not limited by point-to-point radio range; both the phone and device need available connectivity and service.

  1. 01Phone interface

    Select the paired device on your phone, tap ON or OFF, or set a scheduled task.

  2. 024G mobile network

    Commands travel over the internet and reach the device via 4G. No on-site Wi-Fi router is needed.

  3. 03HT-9601

    The controller receives the command and switches its internal relay to carry out the requested action.

  4. 04Connected equipment

    Start or stop compatible pumps, lights or other equipment through the installed circuit. Test switching before regular use.

4G

Overseas versions include one year of data and support power-loss SMS alerts. Provide your destination country and carrier information to confirm network and service suitability.

Site information.
Visible at a glance.

Photos and interfaces come from the original material; physical screen markings are retained.

03 / LCD

Site information.
Visible at a glance.

The LCD brings signal, temperature, humidity and switch status together. Read information at the device and refer to collected ambient readings during remote management.

Ambient temperature / humidity

Standard ambient sensing; discuss customization for other sensors.

Local display & buttons

The LCD and SET, ON and OFF controls are grouped on the front.

RS485 communication

Discuss data integration, including the required interface, protocol and compatibility.

04 / Features

Give routine operations
a clear schedule.

01

Schedules & cycles

Arrange switching times and recurring tasks for compatible lighting, ventilation or equipment.

02

Shared operation

Add users with the device key so colleagues can manage from their own phones.

03

Power-loss alerts

Supports SMS notifications to the main account. Delivery remains dependent on carrier and network service.

Original control interface · Scheduling

Original control interface · Scheduling

05 / HT-9601

Designed around connection,
operation and placement.

External antenna
01

External antenna

A base-mounted antenna and approximately 3 m cable help you choose a suitable signal location.

Terminal cover
02

Terminal cover

A transparent cover shields the terminal area while keeping connections visible.

Device QR code
03

Device QR code

Bind the device using its QR code during initial setup.

SET / ON / OFF buttons
04

SET / ON / OFF buttons

Access basic settings and manual switching at the device.

06 / Applications

From irrigation to lighting.
Across everyday workplaces.

Choose a configuration for the load and installation conditions where remote switching and schedules are useful.

Agricultural irrigation
01

Agricultural irrigation

Manage a compatible pump while working in the field or away from the site.

Aquaculture & aeration
02

Aquaculture & aeration

Schedule compatible aeration equipment and monitor for supply interruptions.

Greenhouses & gardens
03

Greenhouses & gardens

Check ambient readings and manage compatible ventilation or watering equipment.

Industrial & warehouse lighting
04

Industrial & warehouse lighting

Arrange lighting around shifts and reduce trips to switches.

Panels & equipment control
05

Panels & equipment control

Integrate with a suitable control circuit and contactor arrangement.

Tank & pool filling
06

Tank & pool filling

Switch compatible pumps remotely; automatic water-level control requires a separate sensor and control solution.

07 / Setup

From device connection
to phone control.

01

Check network & wiring

Confirm supply, load and network version. Have a qualified installer follow the actual terminal markings.

02

Scan & bind

Open the supported interface, scan the device code and bind your account. The supplied domestic guide shows a WeChat Mini Program.

03

Test & configure

Test local and remote switching, then configure sharing, schedules and the SMS recipient account.

For overseas use, confirm the available app or control interface and account registration method.

08 / HT-9601

Know the parameters. Choose the configuration.

Model
HT-9601 (4G)
Operating voltage
AC 36–400V
Output type
Relay switching
Power stated in source
5kW
Detection current
≤30A
Ambient sensing
Temperature / humidity (standard)
Operation
Phone control + local buttons
Control modes
Latching / non-latching
Timing
Scheduled / cyclic switching
Data communication
RS485
Reference housing size
13.5cm high × 7.8cm wide
Antenna & cable
Approx. 20cm antenna, 3cm base, 3m cable

5kW is the power stated in the supplied material; ≤30A is listed as “detection current”, not a universal switching capacity. Confirm motor starting current, contactors and protection for the actual equipment. Wide input voltage does not mean voltage conversion.

09 / FAQ

A clearer starting point.

Does the site need Wi-Fi?

The device connects through a mobile network and does not require an on-site router. Both phone and device need connectivity, and the device data plan and service must be active.

Can it be used overseas?

Discuss a suitable version for the destination. Overseas versions include one year of data and support power-loss SMS. Confirm local network, interface and account access.

Does sensing mean automatic climate control?

Standard features include ambient temperature and humidity collection and display. Sensor-triggered actions, thresholds and other automation require separate confirmation.

Does the multi-number display mean four outputs?

Output count cannot be inferred from the display artwork. This page covers HT-9601; ask about the appropriate model for two- or four-channel control.

Can it directly switch any 5kW pump?

Do not select by power alone. Check voltage, load type, starting current and protection, including whether a contactor is required.

Will timers and alerts work without a network?

Do not assume all functions work offline. Confirm how timers execute on the selected version; SMS alerts depend on communication conditions.

10 / OEM & ODM

A practical addition
to your product line.

For pump and irrigation dealers, electrical and hardware wholesalers, and lighting or equipment suppliers. Discuss versions, applications and packaging for your customers.

01

OEM / ODM

Discuss product and branding needs

02

Custom packaging

Confirm packaging for your project

03

One-year warranty

Lifetime repair service; confirm applicable terms

HT-9601

Tell us what you want to control.

Share the destination country, equipment nameplate, installation environment and control needs to discuss a suitable HT-9601 configuration.

View original product material +

These are the supplied Chinese source images. Page content is localized; markings and interfaces within the originals are unchanged.